THE CORRECTION OF ELECTRON OUTPUT AT EXTENDED SSD
Abstract
Correction of electron output at extended treatment distance in Mitsubishi ML- 15 MIII Linear Accelerator that available with the solid closed-sided applicator was performed. Comparison of electron outputs from inverse square law (ISL) correction with the outputs from direct measurement in electron field 4x4 to 14x14 cm’, 101-115 cm SSDs with energies at 8,10,12, and 15 MeV revealed that ,with a nominal SSD ,the ISL calculation will provide the corrected output that fitting within ±3 % of the measured output if the field size is equal to or larger than 10x10 cm2 in all gaps and all energies. While with the effective SSD, the calculated outputs were found to agree with all the measured doses in all field sizes, all SSDs, and all energies in the study.
Downloads
Metrics
References
ICRU Report 35. Radiation dosimetry: Electron beams with energies between 1 and 50 MeV. International commission on radiation units measurements. Issued 15 September, 1984
Pohlit W. Dosimetric Zur Betatrontherapie. (Georg Thieme Valag, Stuttgart) 1965
Schroder- Babo P. Determination of virtual electron source in a betatron. Acta Radiol 1983; suppl 364:7-10
Meyer JA, Palta JR, Hogstrom KR. Determination of relative new electron dosimetry measurements techniques on the Mevatron 80. Med Phys, 1984; 11(5): 670-677
Khan FM, Sewchand W, Levitt SH. Effect of air space on depth dose in electron beam therapy. Radiology, 1978; 126: 249-252
Khan FM, Doppke KP, Hogstrom KR, Kutcher GJ, Nath R, Prasad SC, Purdy JA, Rosenfeld M and Werner BI. Clinical electron beam dosimetry: Report of AAPM radiation therapy committee task group No. 25. Med Phys, 1991;18:73-109
Jamshidi A, Kuchnir FT, Reft CS. Determination of the source position for the electron beams for a high energy linear accelerator. Med Phys, 1986; 13: 942-948
Roback DM, Khan FM, Gibbons JP, Sethi A. Effective SSD for electron beams as a function of energy and beam collimation. Med Phys, 1995; 22: 2093-2095
Sweeney LE, Gur D, Bukovitz AG. Scatter component and its effect on virtual source and electron beam quality. IntJ Radiat Oncol Biol Phys, 1981;7:967- 971
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 The ASEAN Journal of Radiology
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Disclosure Forms and Copyright Agreements
All authors listed on the manuscript must complete both the electronic copyright agreement. (in the case of acceptance)