QUALITY ASSURANCE IN RADIOTHERAPY BY IN VIVO DOSIMETRY; ENTRANCE DOSE MEASUREMENT

Authors

  • L. TUNTIPUMIAMORN Department of Radiology, Faculty of Medicine, Siriraj Hopital, Mahidol University
  • V. POLVATSATIAN Department of Radiology, Faculty of Medicine, Siriraj Hopital, Mahidol University
  • B. CHAORUNGRIT Department of Radiological Technology, Faculty of Medical Technology, Mahidol University
  • P. SUKPRASERT Department of Radiological Technology, Faculty of Medical Technology, Mahidol University

Abstract

Quality assurance in radiotherapy by in vivo dosimetry was performed at the Division of Radiation Oncology, Department of Radiology, Siriraj Hospital during Au- gust 1996 to January 1997. The entrance doses of a total number of 467 treatment set- ups (182 cancer patients) undergoing radiation therapy with Cobalt-60 Teletherapy unit were measured with semiconductor detectors. From the study, the global results of the percentage ratios of the measured dose and calculated dose showed a Gaussian fre- quency distribution which a mean and one standard deviation value were 99.2+3.34 %. This meaned that the uncertainty caused by a systematic and random errors in the treat- ment delivery were 0.8% and 3.34% respectively. Eighty-seven percents of all treat- ment set-ups are reliable due to the dose delivered fitted in ±5% of the prescribed dose while the treatments with a large error (2SD) were found in 2.99%. Source of the uncer- tainties in this study arised from incorrect dose calculation, contour irregularities, hu- man mistakes in treatment setting-up, insufficient immobilization and erroneous in the entrance dose measurements themselves.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Herring DF, Compton DMJ. The degree of precision required in the radiation dose delivered in cancer therapy. BJR suppl 5, 1971:51

ICRU Determination of absorbed dose in a patient irradiated by beams of X or Gamma rays in radiotherapy procedures. Report 24, ICRU, Washington 1976.

World Health Organization. Institue of Radiation Hygience, Federal Health Office, Neuherburg, Federal Republic of Germany. Quality assurance in radiothe- rapy. England, 1988

Leunens G, Van Dam J, Dutriex A, Van Der S. Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrace dose mea- surements, a reliable procedure. Radiothe- rapy and Oncology, 1990;17:141-151

Dobbs HJ, Dutriex A, Johansson KA, Leunens G. Treatment preparation and in vivo dosimetry. Regional seminar for Asia and the Pacific on Radiotherpy Dosimetry. Bangkok, Thailand, 28 Nov-1 Dec 1995

Dutriex A. When and how can we improve precision in radiotherapy?. Radiotherapy and Oncology, 1984;2:275-292

Mijnheer BJ, Battermann JJ, Wambersie A. What degree of accuracy is required and can be achieved in photon and neutron therapy?. Radiother. Oncol, 1987;8:237- 252

Goitein M. Calculation of uncertainty in the dose delivered during radiation therapy. Med Phys, 1985;12:608-612

Leunens G, Verstraele J, Van Dam J, Dutriex A, Van Der Schueren E. Expe- rience in in- vivo dosimetry investigation in Leuven. Radiother Oncol, 1991:283

Downloads

Published

2023-04-08

How to Cite

1.
TUNTIPUMIAMORN L, POLVATSATIAN V, CHAORUNGRIT B, SUKPRASERT P. QUALITY ASSURANCE IN RADIOTHERAPY BY IN VIVO DOSIMETRY; ENTRANCE DOSE MEASUREMENT. ASEAN J Radiol [Internet]. 2023 Apr. 8 [cited 2024 Nov. 21];4(2):185-92. Available from: https://asean-journal-radiology.org/index.php/ajr/article/view/441

Issue

Section

Original Article