CORRECTION OF ELONGATION ERROR BY PRODUCING EQUILIBRIUM ERROR

Authors

  • Wanna TRIVITAYARATANA Dept of Radiological Technology, Faculty of Medical Technology, Mahidol University
  • Pichit TRIVITAYARATANA Dept of Radiological Technology, Faculty of Medical Technology, Mahidol University,
  • Chavalit VONGSABARN Dept of Radiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University
  • Songthip NUKROO Kumkunkaew Hospital, Ministry of Public Health

Abstract

The equilibrium error was produced by raising adjustable orthopaedics ruler to the same plane of a PVC phantom of leg to be possible to use teleroentgenographic method. The results showed that by this method the scale error occurred in the same amount as the elongation error. The measured limb length on radiograph was closely approximate to the actual length. It indicated that elongation error was eliminated by producing equilibrium error. The effect of centering the X-ray tube at various levels for measuring the anterior surface of the bone to the film (ASBF) was identified. The center ray of X-ray beam at the upper, middle and lower border of a cross-surface phantom were performed by lateral cross table radiography. The results showed that there is no statistically significant difference between the ranks” of the values of the three measured ASBF (P>0.05). It indicated that X-ray beam centered at skin from ventral to dorsal of leg did not affect the measured ASBF. It is convenience for routine work in JAN. - APR. 1999. Volume V Number I clinical practice.
N.B. : ranks’ is the special term in statistics and is used in cases when the values analyzed are not enough to find the mean. ASBF = Anterior Surface of the Bone to the Film.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Siffert RS. Current concepts review lower limb-length discrepancy. J Bone Joint Surg 1987;69-A:1100-1106.

Siffert RS. The effect of trauma to the epiphysis and growth plate. Skel Radiol 1977;2:21-30.

Tjernstrom B, Jakobsson O, Pech P, Rehnberg L. Reliability of radiological measurements of the distraction gap during leg lengthening. Acta Radiol 1996;37:162-165.

Aaron A, Weinstein D, Thickman D, Eilert R. Comparison of orthoroentgenography and computed tomography in the measurement of limb-leg discrepancy. J Bone Joint Surg 1992;74-A:897-902.

Aitken AGF, Flodmark O, Newman DE, Rilcoyne RF, et al. Leg length determination by CT digital radiography. AJR 1985; 44:613-615.

Altongy JF, Harcke HT, Bowen JR. Measurement of leg length inequalities by micro-dose digital radiographs. J Pediat Orthop 1987; 7: 311-316.

Kogutt MS. Computed radiographic imaging ; use in low dose leg length radiography. AJR 1987;148:1205-1206.

Helm CA, McCarthy S. CT scanograms for measuring leg length discrepancy. Radiology 1984; 154: 802.

Horsfield D, Jones SN. Assessment of inequality in length of the lower limb.J radiography 1986; 52: 223-227.

National Council on Radiation Protection and Measurement (NCRP). Quality control in diagnostic imaging. NCRP report no.99. Maryland: NCRP, 1988.

Soon TN. Radiographic methods of measuring leg length discrepancies. Med Radiographer 1985; 4: 49-55.

Downloads

Published

2023-04-09

How to Cite

1.
TRIVITAYARATANA W, TRIVITAYARATANA P, VONGSABARN C, NUKROO S. CORRECTION OF ELONGATION ERROR BY PRODUCING EQUILIBRIUM ERROR. ASEAN J Radiol [Internet]. 2023 Apr. 9 [cited 2024 Nov. 21];5(1):95-100. Available from: https://asean-journal-radiology.org/index.php/ajr/article/view/471

Issue

Section

Original Article