RADIOPHARMACEUTICAL FOR IMAGING OF LIVER, GALL BLADDER AND BILIARY DUCTS (99mTC-DISIDA)

Authors

  • Nisarut RUKSAWIN Department of Radiology, Siriraj Hospital

Abstract

The cholescintigraphic procedures have played a significant role in diagnosis of hepatobiliary disorder in Thailand. Especially 99mTc-DISIDA scintigrams of infants are the diagnosis procedures of choice for biliary atresia because it is difficult to diagnose by other means for examples CT and ultrasonography. The synthesis of DISIDA (2,6- diisopropylacetanilide iminodiacetic acid), was prepared successfully since 1983 at Section of Nuclear Medicine, Siriraj Hospital. The DISIDA compound was made into DISIDA instant kits by adding appropriate amount of stannous chloride. Each kit contained 10 mg of DISIDA and 0.25 mg of SnCl, 2H,O. Radiochemical purity was good at 2-4 ml of Na 99mTcO, (activity of 1 to 50 mCi) and lasted for 6 hours. The Lyophilized form of DISIDA-kit had stability not less than 1 year. No reports of unfavorable effects on patients with this product during the past 14 years.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Chervu R, Nunn A, Loberg M. Radiophar- maceuticals for hepatobiliary imaging. Seminars in Nucl Med 1982;12:5-17.

Gliedman M, Wilk P. A surgeon's view of hepatobiliary scintigraphy. Seminars in Nucl Med 1982;12:2-4.

Rosenthall L. Cholescintigraphy in the presence of jaundice utilizing 99mTc-IDA. Seminars in Nucl Med 1982;12:53-63.

Weissmann H, Gliedman M, Wilk P, Sugarman L, Badia J, Guglielmo K, Freeman L. Evaluation of the postoperative patient with 99mTc-IDA cholescintigraphy. Seminars in Nucl Med 1982;12:27-52.

Noronha O, Sewatkar A, Ganatra R, Subramanian G. The transport, hepatobiliary distribution and clearance of 99mTc-Sn- Lidocaine iminodiacetic acid. Int J Nucl Med and Biol 1977;4:122-8.

Ruksawin N. Leukocytes labelling with 99mTc. Thesis, The University of Texas, M.D. Anderson Hospital and Tumor Institute, Houston, Texas, U.S.A. 1973.

Manual of radiopharmaceutical preparation. Division of nuclear medicine, Institute of medical and veterinary science, Adelaide, South Australia.

Loberg M, Cooper M, Harvey E, Cally P, Faith W. Development of new radiophar- maceuticals based on N-substitution of imin- odiacetic acid. J Nucl Med 1976;17:633-8.

Callery P, Faith W, Loberg M, et al. Tissue distribution of 99mTc and 14C labelled N- (2,6-dimethylphenylcarbamoyl-methyl) im- inodiacetic acid. J Med Chem 1976;19:962.

Ruksawin N, Na Songkhla S, Pleehachinda R, Buranapong P, Suwanik R. Radiophar- maceutical for bone scanning. The Thai journal of radiology 1981;18:5-10.

U.S. Pharmacopeia XVIII, 18th revision, Mack publishing company, Easto PA. 18042,1970;856-87.

Weissmann H, Frank M, et al. Rapid and accurate diagnosis of acute cholecystitis with 99mTc-HIDA cholescintigraphy. AJR 1979;132:523-8.

Pare P, Shaffer EA, Rosenthall L. Nonvisua- lization of the gallbladder by 99mTc-HIDA cholescintigraphy as evidence of cholecy- stitis. Can Med Assoc J 1978;118:384-6.

Cheng TH, Davis MA, Seltzer SE, et al. Evaluation of hepatobiliary imaging by radionuclide scintigraphy, ultrasonography, and contrast cholangiography. Radiology 1979;133:761-7.

Ekelman EA, Cameron JL, Colman M, et al. A test for patency of cystic duct in acute cholecystitis. Ann Intern Med 1975;82:318-22.

Stadalnik RC, Matolo NM, Jansholt AL, et al. Technetium-99m pyridoxylidenegluta- mate (P.G.) cholescintigraphy. Radiology 1976;121:657-61.

Down RHL, Arnold J, Goldin A, et al. Comparison of accuracy of 99mTc- pyridoxy- lidene-glutamate scanning with oral cho- lecystography and ultrasonography in diag- nosis of acute cholecystitis. Lancet 1979;- 2:1094-7.

Weissmann H, Sugarman L, Frank M, et al. Serendipity in Technetium-99m dimethyl iminodiacetic acid cholescintigraphy. Radi- ology 1980;135:449-54.

Downloads

Published

2023-04-08

How to Cite

1.
RUKSAWIN N. RADIOPHARMACEUTICAL FOR IMAGING OF LIVER, GALL BLADDER AND BILIARY DUCTS (99mTC-DISIDA). ASEAN J Radiol [Internet]. 2023 Apr. 8 [cited 2024 Nov. 21];4(1):1-4. Available from: https://asean-journal-radiology.org/index.php/ajr/article/view/412

Issue

Section

Original Article