ACCURACY OF THE MRA FOR THE DETECTION OF INTRACRANIAL ANEURYSM AS COMPARED TO THE CATHETER ANGIOGRAM

Authors

  • Pichest METARUGCHEEP Department of neuroradiology, Prasat Neurological Institute
  • Nitat KIATHIRANNON Department of neuroradiology, Prasat Neurological Institute
  • Somsak CHANYAWATTIWONGSE Department of neuroradiology, Prasat Neurological Institute

Keywords:

MRA, SAH, Aneurysm, SAH = Subarachnoid Haemorrhage, SCA = Superior Cerebellar Artery, 3DTOF = 3 dimentional Time of Flight, DAVF = Dural AV Fistular, MIP = Maximum Intensity Projection

Abstract

Purpose: To assess the role of MRA for detection of intracranial aneurysm as compared to catheter angiogram by using standard method of post processing (MIP) in blinded-reader study.

Material and Method: Two hundred vessels were examined with catheter angiogram and 3DTOF MRA in SO patients with SAH (38 aneurysms ,1 DAVF and 13 patients with no aneurysm at DSA). MRA were interpreted by neuroradiologist blinded to the DSA results for presence, location, size and morphology of the aneurysm.

Results: Mean sensitivity for detection of aneurysm was 92.1% specificity 100%,positive predictive value 100%and negative predictive value 81.3%. 38 aneurysms were found; A-com 14, P-com 8, MCA 7, Basilar 4, ICA 3, SCA 1, vertebral 1, 1 DAVF and 13 no aneurysm. True positive 35, true negative 13,false positive 0 and false negative 3.

Conclusion: MRA with standard post processing can result in high sensitivity and specific studies for the diagnosis of intracranial aneurysm that are of sufficient size to be considered for surgical treatment. The positive predictive value is also very high but the negative predictive value is not high enough. Therefore, in negative study of MRA, cather angiogram is still recommended.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Sahs AL, Perret GE, Locksley HB, et al. Intracranial aneurysms and subarachnoid hemorrhage: a cooperative study. Philadelphia, Pa: Lippincott, 1969

Wiebers DO, Torner JC, Meissner I. Impact of unruptured intracranial aneurysms on public health in the United States. Stroke 1992; 23:1416-19

Hankey GJ, Warlow CP, Sellar RJ. Cerebral angiographic risk in mild cerebrovascular disease. Stroke 1990; 21: 209-222.

Bromberg, J, Rinkel G, Algra A, et al. Subarachnoid hemorrhage in first and second degree relatives of patients with subarachnoid hemorrhage. Br Med J 1995; 311:288-289.

Schievink W, Schaid D, Michels V, Piepgras D. Familial aneurysmal subarachnoid hemorrhage: a community-based study. J Neurosurg 1995; 83:426-429.

Obuchowski N, Modic M, Magdinec M. Current implications for the efficacy of noninvasive screening for occult intracranial aneurysms in patients with a family history of aneurysms. J Neurosurg 1995; 83:42-49

Rosenorn J, Eskesen V, Schmidt K. Unruptured intracranial aneurysms: an assessment of the annual risk of rupture based on epidemiological and clinical data. Br J neurosurg 1988;2:369-378

Weir BK A. Intracranial aneuryams. Curr Opin Neurol Neurosurg 1990; 3:55-62.

Solomon RA, Fink ME, Pile-Spellman J. Surgical management of unruptured intracranial aneurysms. J Neurosurg 1994; 80:440-446.

Anderson CM, Saloner D, Tsuruda JS, Shapeero LG, Lee RE. Artifacts in maximum intensity projection display of MR angiogram. AJR 1990; 154:623-629.

Atlas SW, Listerud J, Chung W, Flamm E. Intracranial aneurysms: depiction on MR angiograms with a multifeature-extraction, ray-tracing postprocessing algorithm. Radiology 1994;192:129-139.

Ross JS, Masaryk Tj, Modic MT, Ruggieri PM, Haacke Em, Selman WR. Intracranial aneurysms: evaluation by MR angiography. AJNR 1990; 11:449-456.

Huston J, Rufenact DA, Ehman RL, Wiebers DO. Intracranial aneurysms and vascular malformations: comparison of time-of-flight and phase-contrast MR angiography. Radiology 1991; 181:721- 730.

Korogi Y, Takahashi M, Mabuchi N,et al. Intracranial aneurysms: diagnostic accuracy of three dimensional, Fourier transorm time-of-flight MR angiography. Radiology 1994; 193:181-186.

Scott WA, Lisa S, Herbert IG, et al. Intracranial aneurysms detection and characterization with MRA with use of advanced post processing technique in blinded-reading study. Neuroradiology 1997; 203:807-814.

Listerud J, Atlas SW, McGowan JC, Butler N. TRAP: traced ray by array processor (abstr). In: Book of Abstracts: Society of Magnetic Resonance in Medicine 1991.

Berkeley, Calif: Society of Magnetic Resonance in Medicine, 1991; TSi. Atlas SW, Listerud J. MR angiography of the circle of Willis and middle cerebral artery bilurcation: traced ray with array processor versus maximum intensity projection reconstruction (abstr). Radiology 1991;181(P):256.

Hanley JA, McNeil Bj. The meaning and use of the area under a receiver operation characteristic curve. Radiology 1982; 143: 29-36.

Heiserman JE, Drayer BP, Fram EK, et al. Carotid artery stenosis: clinical efficacy of two-dimenstional — time-of-flight MR angiography. Radiology 1992; 182:761- 768.

Huston J, Lewis BD. Wiebers DO, Meyer FB, Riederer SJ, Weaver AL. Carotid artery: prospective blinded comparision of two-dimensional __ time-of-flight MR angiography with conventional angiography and duplex US. Radiology 1993; 186:339-344.

Litt Aw, Eidelman EM, Pinto RS, et al. Diagnosis of carotid artery stenosis: comparison of 2DFT time-of-flight MR angiography with contrast angiography in 50 patients. AJNR 1991; 12:149-154.

Masaryk TJ, Ross JS, Modic MT, Lenz GW, Haacke EM. Carotid bifurcation: MR imaging-work in progress. Radiology 1988; 166:461-466.

Mitt] RL, Broderick M, Carpenter JP, et al. Blinded reader comparision of magnetic resonance angiography and duplex ultrasonography for carotid artery bifurcation stenosis. Stroke 1994; 25:4-10.

Polak JF, Bajakian RL, O’Leary DH, Anderson MR, Donaldson MC, Jolesz FA. Detection of internal carotid artery artery stenosis: comparison of MR angiography, color Doppler, sonography, and arteriography. Radiology 1992; 182:35-40.

Masaryk TJ, Modic MT, Ruggieri PM, et al. Three-dimensional (volume) gradient-echo imaging of the carotid bifurcation: preliminary clinical experience. Radiology 1989; 171:801-806.

Atlas SW. MR angiography in neurological disease. Radiology 1994; 193: 1-16.

Eng J, Ceckler TL, Balaban RS. Quantitative 1H magnetization transfer imaging in vivo. Magn Reson Med 1991; 17:304-314.

Edelman RR, Ahn SS, Chien D, et al. Improved time-of-flight MR angiography of the brain with magnetization transfer contrast. Radiology 1992; 184: 395-399.

Dumoulin CL, Souza SP, Walker MF, et al. Three-dimensional phase contrast angiography. Magn Reson Med 1989; 9: 139-149.

Juvela S, Porras M, Heiskanen O. Natural history of unruptured intracranial aneurysms: a long term follow-up study. J Neurosurg 1993; 79:174-182.

Downloads

Published

2023-04-16

How to Cite

1.
METARUGCHEEP P, KIATHIRANNON N, CHANYAWATTIWONGSE S. ACCURACY OF THE MRA FOR THE DETECTION OF INTRACRANIAL ANEURYSM AS COMPARED TO THE CATHETER ANGIOGRAM. ASEAN J Radiol [Internet]. 2023 Apr. 16 [cited 2024 Dec. 21];9(1):17-23. Available from: https://asean-journal-radiology.org/index.php/ajr/article/view/624

Issue

Section

Original Article

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.